Newshot

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

Summary

arXiv:2611.27390v1 Announce Type: new Abstract: On-premise clinical AI agents must auto-accept high-confidence diagnoses, deferring others to clinician review, yet token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute. We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol. Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels. Calibration freezes a nominal top-50% threshold, selecting single-run, five-run consistency, or full-deferral tiers by whether the one-sided 95% Wilson lower confidence bound of pass rate among accepted cases meets the 95% clinical target line. Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases, MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% comp…

Original text(via arXiv cs.AI)

Computer Science > Artificial Intelligence

Title:Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

Abstract:On-premise clinical AI agents must auto-accept high-confidence diagnoses, deferring others to clinician review, yet token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute. We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol. Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels. Calibration freezes a nominal top-50% threshold, selecting single-run, five-run consistency, or full-deferral tiers by whether the one-sided 95% Wilson lower confidence bound of pass rate among accepted cases meets the 95% clinical target line. Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases, MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute; CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier, capping calibration false-certification rate at 0.00%-3.50%.
Subjects:Artificial Intelligence (cs.AI)
Cite as:arXiv:2611.27390 [cs.AI]
(or arXiv:2611.27390v1 [cs.AI] for this version)
https://doi.org/10.48550/arXiv.2611.27390 arXiv-issued DOI via DataCite (pending registration)

Submission history

Access Paper:

Additional Features

  • Audio Summary

Current browse context:

References & Citations

  • Google Scholar
  • Semantic Scholar

BibTeX formatted citation

Bookmark

Bibliographic and Citation Tools

Code, Data and Media Associated with this Article

Demos

Recommenders and Search Tools

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

The text above was extracted automatically from the source page and may miss images, tables or code blocks. The original is authoritative.

Published by arXiv cs.AI
This site only summarises and aggregates; copyright stays with the original author. Headlines and summaries follow the source — where they differ, the original wins.
Read the original ↗