Summary

arXiv:2611.23345v1 Announce Type: new Abstract: Wearables and monitors record few electrocardiogram (ECG) leads; most diagnostic tools assume 12 leads. BiMa-ECGSR reconstructs the 12-lead ECG from reduced lead sets with a bidirectional Mamba state-space encoder--decoder, as regression (BiMa-SR) or diffusion (DiBiMa-SR). Models were trained on PTB-XL for six input sets (I; II; I+II; I+II+V1; I+II+V2; I+II+V1+V4), see only the measured leads at inference, and were tested on the PTB-XL test fold (2,198 records) and two external cohorts (Georgia, 10,275 records; Chapman-Shaoxing/Ningbo, 43,559). From lead II alone, the pooled median Pearson correlation (PCC) over the 11 predicted leads was 0.914 on PTB-XL, against 0.784 for a least-squares linear filter (lead I: 0.906 against 0.789). As limb leads are exactly derivable from I and II, multi-lead inputs were compared on predicted chest leads: 0.939 against 0.849 for I+II and 0.979 against 0.962 for I+II+V1+V4. BiMa-SR exceeded the linear com…

Original text(via arXiv cs.LG)

Computer Science > Machine Learning

Title:BiMa-ECGSR: reconstructing the 12-lead ECG from reduced lead sets with bidirectional state-space models

Abstract:Wearables and monitors record few electrocardiogram (ECG) leads; most diagnostic tools assume 12 leads. BiMa-ECGSR reconstructs the 12-lead ECG from reduced lead sets with a bidirectional Mamba state-space encoder--decoder, as regression (BiMa-SR) or diffusion (DiBiMa-SR). Models were trained on PTB-XL for six input sets (I; II; I+II; I+II+V1; I+II+V2; I+II+V1+V4), see only the measured leads at inference, and were tested on the PTB-XL test fold (2,198 records) and two external cohorts (Georgia, 10,275 records; Chapman-Shaoxing/Ningbo, 43,559). From lead II alone, the pooled median Pearson correlation (PCC) over the 11 predicted leads was 0.914 on PTB-XL, against 0.784 for a least-squares linear filter (lead I: 0.906 against 0.789). As limb leads are exactly derivable from I and II, multi-lead inputs were compared on predicted chest leads: 0.939 against 0.849 for I+II and 0.979 against 0.962 for I+II+V1+V4. BiMa-SR exceeded the linear comparator in all 18 configuration--cohort pairs (by 0.012--0.136), a margin that shrank as chest leads were added. From lead II, regression was more accurate than diffusion (DiBiMa-SR: 0.903 one-step, 0.862 with six DDIM steps). A 12-lead classifier trained only on real ECGs reached a superclass macro AUROC of 0.912 on real PTB-XL ECGs, 0.843 on reconstructions from lead II and 0.908 from I+II+V1+V4; externally, reconstructions from three or four leads scored within 0.004 of real ECGs. BiMa-SR (2.68\,M parameters) takes 45.8 ms per 10-s record on a GPU. Reconstruction makes reduced-lead recordings usable by 12-lead tools; it cannot add information absent from the measured leads.
Subjects:Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI)
Cite as:arXiv:2611.23345 [cs.LG]
(or arXiv:2611.23345v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2611.23345 arXiv-issued DOI via DataCite (pending registration)

Submission history

Access Paper:

  • HTML (experimental)

Additional Features

  • Audio Summary

Current browse context:

References & Citations

  • Google Scholar
  • Semantic Scholar

BibTeX formatted citation

Bookmark

Bibliographic and Citation Tools

Code, Data and Media Associated with this Article

Demos

Recommenders and Search Tools

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

The text above was extracted automatically from the source page and may miss images, tables or code blocks. The original is authoritative.

Published by arXiv cs.LG
This site only summarises and aggregates; copyright stays with the original author. Headlines and summaries follow the source — where they differ, the original wins.
Read the original ↗